SINGLE PACKAGE ROOFTOP UNITS WITH X-VANE™ FAN TECHNOLOGY:
GAS HEATING/ELECTRIC COOLING (RGV) 3 - 6 TON
AND ELECTRIC COOLING/OPTIONAL ELECTRIC HEAT (RAV) 3 - 6 TON
K = 208/230-1-60, H = 208/230-3-60, L = 460-3-60, S = 575-3-60
The new 3 to 6 Ton RGV/RAV series rooftop units (RTU) with X-Vane™ Fan Technology provides value added benefits never seen in this type of equipment before. New major design features include:
Patent pending, the industry’s first beltless direct-drive vane axial fan for rooftop units with electric commutated variable speed motor.
Reliable fixed speed scroll compressor on 3-5 ton sizes and 2 stage scroll technology on 6 ton sizes.
Upgraded unit control board with intuitive indoor fan adjustment.
Reliable copper tube / aluminum fin condenser coil with 5/16-in. tubing to help reduce refrigerant charge versus prior designs.
New outdoor fan system with rugged, lightweight high impact composite fan blade.
Installation ease
All RGV/RAV units are field convertible to horizontal air flow, which makes it easy to adjust to unexpected job site complications. RGV/RAV rooftop units up to 6 tons are specifically designed to fit on our existing roof curbs dating back to 1989 for worry-free original fit. Also, our large control box gives you room to work and room to mount accessory controls. Intuitive controls make setting up the required fan speed simple and accurate. Access to the blower section is no longer needed with the new design.
Easy to maintain
with the new Vane Axial fan and direct drive ECM motor, there is no longer a need to adjust belts or pulleys as in past designs. This frees up maintenance and installation time.
Easy access handles provide quick and easy access to all normally serviced components. Our “no-strip” screw system has superior holding power and guides screws into position while preventing the screw from stripping the unit’s metal. Sloped, corrosion resistant composite drain pan sheds water and won’t rust. RGV units are designed with a naturally draining heat exchanger. Unlike positive pressure heat exchangers, this does not need to be periodically, manually drained. This saves labor and maintenance expense.
Easy to use
The newly re-designed Unit Control Board puts all connections and troubleshooting points in one convenient place. Most low voltage connections are made to the same board for easy access. Setting up the fan is made simple by an intuitive switch and rotary dial arrangement. RGV/RAV rooftops have high and low pressure switches, a filter drier, and 2-in. filters standard.
X-Vane Fan Technology
Direct drive X-Vane Fan Technology indoor fan system uses vane axial fan design and electrically commutated motors. This new Vane Axial design over past belt drive systems has 75% fewer moving parts, uses up to 40% less energy and has no fan belts, blower bearings, or shaft.
Design features include:
Single-stage units deliver SEERs up to 14.0 and EERs up to 11.8. Two-stage units deliver IEERs up to 15.2 and EERs up to 11.2.
All models are capable of either vertical or horizontal airflow.
RGV/RAV rooftop units (RTU) were designed by customers for customers. with “no-strip” screw collars, handled access panels, and more the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton RGV/RAV rooftop unit (RTU) provides optimum comfort and control from a packaged rooftop. RGV/RAV Product Specifications
Features/Benefits Value-added features include:
Optional Hot Gas Re-Heat dehumidification system for improved part load humidity performance
R-410A refrigerant
Single point gas and electrical connections
3 to 5 ton models use fixed refrigerant metering devices and 6 ton models use a TXV
Scroll compressors with internal line-break overload protection
Operating efficiency and flexibility
The RGV/RAV rooftops exceed ASHRAE (American Society of Heating, Refrigerating, and Air-Conditioning Engineers) 90.1-2016, IECC1 (International Energy Conservation Code) IECC-2018 minimum efficiency requirements.
Field convertible airflow
All RGV/RAV 3 to 6 ton units are field-convertible to horizontal airflow, which makes it easy to adjust to unexpected job site complications.
Comfort control
Our patented Hot Gas Re-Heat dehumidification system is an all-inclusive factory-installed option on gas heating/electric cooling and electric cooling/electric heat models. This system provides reliable, flexible operation to meet indoor part load sensible and latent requirements.
Features and Specification
Weight
511
AHRI - Usage
Packaged
Air Flow Direction
Convertible
Blower Motor HP
1 11/25 HP
Blower Motor RPM
239-2390
Blower Motor Speeds
Variable
Blower Motor Type
ECM (Electronically Commutated Motor)
Blower Wheel Size
16 3/5
Brand
Tempstar
CBU - Compressor Bearing Unit
Yes
CFM Cooling
1500-2500
Compressor
Scroll
Condenser Motor HP
1/4 HP
Condenser Motor RPM
1100
Condenser Motor Speeds
1 (Single)
Condenser Motor Type
Direct Drive
Cooling Capacity
58500
Cubic Measurement
66.9766
Cycle/Hertz
60 Hz
Drain Connection Quantity
1
Drain Connection Size
3/4
Drive Type
Direct
EER
11.2
Electric Heat Range [kW]
0
Energy Star Rated
No
Equipment Type
Straight Cool
Evaporator Coil Metering Device
Accutrol - Fixed Metering Device
Fan Diameter
23
Filter Size
(2) 16" x 25" x 2" RA Filter, (1) 20" x 24" x 1" OA Inlet Screen
Height
33.375
Length
46.625
Locked Rotor Amps (LRA)
110
Number of Fan Blades
1
OPT Code
1PRAV060H0FA0AAA
Phase
Three
Package Weight
551
Product Family
RAV
Prop 65
Yes
Rated Load Amps (RLA)
16
Refrigerant
R-410A
Sound Level (dBA)
79-85.6
Stage
Single
Tonnage
5
UL Listed
Yes
UOM
EA
UPC
See Optical
Voltage
208-230 VAC
Width
74.375
Maximum Overcurrent Protection (MOCP)
45